GFEVT500‑K‑51E Series Square‑Body Fast‑Acting DC Fuse Links (Size 1#,100‑800A,500Vdc)

GFEVT500‑K‑51E Size1# aR Fast‑Acting DC Fuse,100‑800A 500Vdc,50kA interrupting capacity.</strong> Optional with / without blow‑indicator, UL248‑13 & IEC60269‑4, RoHS REACH for energy‑storage battery pack protection. Request datasheet & quotation.

20+ Years Experience

Over 20 years in electrical protection and fuse manufacturing.

 

Strict Quality Control

Rigorous testing ensures reliable product performance.

 

GFEVT500‑K‑51E Series Square‑Body Fast‑Acting DC Fuse Links (Size 1#,100‑800A,500Vdc)

Product Overview

The GFEVT500-K-51E Size1# is a DC fuse designed as an aR fast-acting square-body fuse for energy-storage battery pack protection. This fuse supports 500Vdc at 100-800A with 50kA interrupting capacity.

,GFEVT500‑K‑51E is GFEV Size1# square‑body aR‑class fast‑acting DC semiconductor fuse link, rated 500Vdc, 100A‑800A. Two mechanical configurations are available: K‑51E (standard): equipped with fuse blow indicator; KN‑51E (optional): without fuse blow indicator.

Optimized for heavy‑duty DC fault‑protection. Max interrupting capacity reaches 50kA@500Vdc, ultra‑short time constant ≤3 ms, minimum breaking current ≥3×In. Features excellent DC breaking performance, low watt loss, ≥20g high‑frequency vibration resistance, superior cycling capability. Complies with UL248‑1/248‑13, IEC60269‑1/60269‑4, RoHS; REACH declaration available on request. Widely used for battery‑pack, energy‑storage system and DC relay backup protection.

Note:Product specifications subject to change without prior notice.

Key Features & Benefits

‑ ✔ aR Fast‑Acting DC‑optimized Design: Time constant ≤3 ms, extremely fast opening upon high‑fault‑current events, reliably protect semiconductors & battery circuits.

‑ ✔ High Breaking Performance: 50 kA max interrupting capacity @500Vdc; minimum breaking current ≥3 In.

‑ ✔ Two Indicator Options: Standard K‑51E with blow indicator; optional KN‑51E without indicator for compact installation.

‑ ✔ Low Watt Loss: Reduce heat accumulation, improve whole‑system energy efficiency.

‑ ✔ Superior Mechanical Reliability: ≥20 g high‑frequency vibration resistance, excellent shock‑impact endurance for harsh new‑energy site conditions.

‑ ✔ Comprehensive Environmental Adaptability: Support derating calculation for ambient‑temperature, altitude and forced‑air‑cooling scenarios.

‑ ✔ Full‑standard Compliance: UL248‑13, IEC60269‑4; RoHS compliant; REACH document available upon request.

‑ ✔ Superior cycling capability, outstanding anti‑current‑impulse performance.

General Technical Specifications

ItemParameter
SeriesGFEVT500‑K‑51E Series, Size 1#
Rated Voltage500 Vdc
Rated Current Range100A ~ 800A
Utilization ClassaR (semiconductor protection)
Max Interrupting Capacity50 kA @500 Vdc
Minimum Breaking Current≥3 In
Time Constant≤3 ms
VersionsK‑51E (with indicator‑standard); KN‑51E (without indicator‑optional)
Vibration Resistance≥20 g high‑frequency vibration
Normal Operating Ambient Temp‑5℃ ~ +40℃
Allowable Operating Ambient Temp‑40℃ ~ +85℃
Storage Temperature‑40℃ ~ +120℃
StandardsUL248‑1 / UL248‑13; IEC60269‑1 / IEC60269‑4; RoHS, REACH available
Recommended Continuous Working Current≤75 % of fuse rated In

Model List & Electrical Ratings (50kA@500Vdc)

Replace suffix XX with K‑51E(with indicator) or KN‑51E(without indicator).

Part NumberRated Current(A)SizeMelting A²sClearing A²tPower Loss(W,100%)
GFEVT500‑100XX‑51E1001#820737023
GFEVT500‑125XX‑51E1251#13401191028
GFEVT500‑160XX‑51E1601#24102155035
GFEVT500‑200XX‑51E2001#30302691038
GFEVT500‑250XX‑51E2501#50504568052
GFEVT500‑275XX‑51E2751#61405922055
GFEVT500‑315XX‑51E3151#79107506064
GFEVT500‑350XX‑51E3501#1052010026068
GFEVT500‑400XX‑51E4001#1506014382072
GFEVT500‑450XX‑51E4501#2083020516078
GFEVT500‑500XX‑51E5001#2676026415087
GFEVT500‑550XX‑51E5501#3652036315092
GFEVT500‑630XX‑51E6301#53800554220100
GFEVT500‑700XX‑51E7001#71550742770102
GFEVT500‑800XX‑51E8001#995401035000113

Dimension Drawings & Two Versions

Insert engineering drawing images here:

‑ H3:K‑51E:Standard version drawing with fuse blow indicator

‑ H3:KN‑51E:Optional version drawing without indicator

Important Reminder:

  1. Refer to original datasheet for full dimension tolerances for mechanical design.
  2. For high‑altitude, high‑ambient‑temp closed‑cabinet installation, rated‑current derating calculation is mandatory.

Time‑Current & Derating Curves Reference

Insert three charts:

  1. Time‑Current characteristic curve (accuracy ±15 % current error; minimum breaking current=3 In)
  2. Ambient‑temperature derating coefficient curve
  3. Altitude rated‑current correction coefficient curve

Key application notes: ‑ For ambient temperature >40 ℃, apply temperature‑derating factor Kt to reduce allowable continuous current. ‑ For altitude 2000‑4500 m closed‑environment cabinet: derate 2‑5 % rated‑current per 1000 m elevation increase. ‑ Forced air cooling can improve continuous‑current capacity, refer Kv wind‑speed correction curve.

Typical Application Fields

‑ Battery Energy‑Storage System (BESS), battery pack main‑circuit over‑current protection ‑ BMS & DC relay backup protection ‑ Renewable‑energy energy‑storage power conversion equipment ‑ Industrial heavy‑current DC power supply & rectifier units ‑ Stationary energy‑storage cabinet & energy‑storage container ‑ Heavy‑duty DC equipment with high short‑circuit‑fault‑risk

Standards & Compliance

‑ Reference Standard: UL 248‑1, UL 248‑13; IEC 60269‑1, IEC 60269‑4 ‑ Environmental: RoHS Compliant; REACH declaration available upon request ‑ Mechanical: High vibration & shock resistance ≥20 g

Packing & Sample Inquiry

‑ Standard packing: Factory bulk carton packing. ‑ Engineering samples available for performance‑verification testing. ‑ MOQ negotiable for project orders. ‑ Send inquiry to obtain full datasheet, 2D drawing, I²t data sheet and quotation.

Frequently Asked Questions

1: What is difference between K‑51E and KN‑51E suffix?

1: K‑51E (standard): built‑in fuse blow indicator; KN‑51E (optional): no fuse‑blow indicator for compact space‑saving installation.

2: What is time‑constant for GFEVT500‑K‑51E fuse?

2: Time constant ≤3 ms, ultra‑fast clearing for DC short‑circuit faults; minimum breaking current ≥3×In.

3: What derating factors should engineers consider for this fuse?

3: Three critical factors: ambient‑temperature(Kt), installation altitude(Ka), forced‑air‑cooling(Kv). In closed cabinet above 40 ℃ or altitude >2000 m, rated‑current must be properly derated. Recommended continuous operating current ≤75 % nominal In under standard‑condition.

4: What certification documents can you provide?

4: RoHS compliant; REACH declaration document can be provided on customer request; comply with UL248‑13 & IEC60269‑4 standards.

5: What is max interrupting rating?

5: Max interrupting capacity is 50 kA @500 Vdc, minimum breaking current ≥3×In.

Bottom CTA block Need datasheet, drawing, sample or quotation for GFEVT500‑K‑51E series square‑body dc fuse? Submit inquiry form, our technical‑sales team will reply you within 24 working hours.

GFEVT500‑K‑51E Size1# square‑body fast‑acting dc fuse EssFuse