GFHVT1500‑A‑59ES 1500Vdc Fast‑Acting Fuse 100‑630A

GFHVT1500‑A‑59ES flush‑end DC fuse,1500Vdc,100‑630A,aR 50kA interrupt. UL/IEC for compact BESS & battery‑module protection. Download datasheet.

20+ Years Experience

Over 20 years in electrical protection and fuse manufacturing.

 

Strict Quality Control

Rigorous testing ensures reliable product performance.

 

GFHVT1500‑A‑59ES Series 1500Vdc Fast‑Acting Flush‑End Square‑Body Fuse 100‑630A

Product Overview

The GFHVT1500‑A‑59ES series is compact square‑body fast‑acting aR fuse link with flush‑end contact terminals, purpose‑built for high‑energy DC circuits. Rated for 1500Vdc, current range 100A‑630A, maximum interrupting capacity 50kA@1500Vdc, minimum breaking current ≥5×In.

This flush‑end contact design optimizes space‑saving cabinet layout, ideal for compact energy‑storage racks and battery‑module internal protection. It delivers outstanding DC fault‑clearing performance, low watt‑loss, high cycling endurance and ≥20g shock‑vibration resistance. Two‑pcs M10 mounting holes for reliable busbar assembly.

Note: Ratings 450‑630A certification pending; consult factory before project specification.

Key Features & Benefits

  • ✅ Flush‑end contact terminal design, space‑saving for compact cabinet / rack layout
  • ✅ Rated voltage 1500V DC, reduce conductor cost and improve overall system efficiency
  • ✅ Fast‑acting aR semiconductor‑protection characteristic, time constant ≤5 ms
  • ✅ High interrupt rating: 50 kA @1500Vdc, minimum breaking current ≥5In
  • ✅ Low power loss, superior charge‑discharge cycling capability
  • ✅ Excellent mechanical shock & vibration resistance (≥20g)
  • ✅ 2 pcs M10 mounting holes for flush‑end busbar connection
  • ✅ RoHS compliant, REACH statement available upon request
  • ✅ Complies with UL 248.1 / UL 248.13, IEC 60269‑1 / IEC 60269‑4

Main Electrical Specifications

ParameterSpecification
Rated Voltage1500 Vdc
Rated Current Range100A‑630A
Fuse ClassaR Fast‑acting
Max Interrupt Capacity50 kA @1500Vdc
Minimum Breaking Current≥5×In
Time Constant≤5 ms
Terminal TypeFlush‑end contact (M10 mounting holes)
Storage Temperature-40 ℃ ~ +120 ℃
Normal Operating Ambient-5 ℃ ~ +40 ℃
Allowable Operating Temperature-40 ℃ ~ +85 ℃

Note: Recommended continuous operating current ≤75 % of fuse nominal rating under standard ambient‑temperature conditions. 450‑630A models certification in progress, please contact engineering team for evaluation.

Part Numbering Explanation

Example Model: GFHVT1500‑400A‑59ES

CodeDefinition
GFManufacturer Code (GFEV)
HVHigh‑Speed / Fast‑Acting
TCeramics Body
1500Rated Voltage:1500Vdc
400Rated Current(A)
ATerminal: Flush‑end contact
59ESSeries Code

Mechanical Dimensions & Installation

Flush‑end contact terminal with two M10 mounting holes, compact square housing for narrow‑space rack installation.

Installation note: M10 screw hole; max hole depth 11.5 mm, minimum thread length 9.5 mm. Apply proper tightening torque to avoid over‑heating contact points.

Full Part List Table

Note: ○ Pending = Certification in‑progress, consult factory. ●=Compliant.

Part NumberFuse AmpsMelting A²sClearing A²sPower Loss 80%In(W)Power Loss 100%In(W)RoHSREACH
GFHVT1500‑100A‑59ES100A237088574153●●
GFHVT1500‑125A‑59ES125A4890132194760●●
GFHVT1500‑160A‑59ES160A7192194405064●●
GFHVT1500‑200A‑59ES200A11066299076886●●
GFHVT1500‑250A‑59ES250A179404848086107●●
GFHVT1500‑315A‑59ES315A3056882610102127●●
GFHVT1500‑350A‑59ES350A40655109878109136●●
GFHVT1500‑400A‑59ES400A58496158090121151●●
GFHVT1500‑450A‑59ES450A78890213215128161○ Pending○ Pending
GFHVT1500‑500A‑59ES500A101503274330139174○ Pending○ Pending
GFHVT1500‑550A‑59ES550A125982340490155194○ Pending○ Pending
GFHVT1500‑630A‑59ES630A185020500100162203○ Pending○ Pending

Application Fields

  • ⚡ Compact Battery‑Energy‑Storage System(BESS) main‑circuit short‑circuit protection
  • ⚡ Lithium‑ion battery‑module internal short‑circuit protection
  • ⚡ Backup short‑circuit protection for DC relays & DC contactors
  • ⚡ Narrow‑space energy‑storage rack / cabinet DC busbar protection
  • ⚡ Maintenance safety disconnector / DC isolation for industrial DC equipment

Standards & Certifications

Standard / CertificateStatus
UL 248.1, UL 248.13Complied (≤400A); Pending (450‑630A)
IEC 60269‑1, IEC 60269‑4Complied (≤400A); Pending (450‑630A)
RoHSCompliant
REACHDeclaration available upon request

Important: 450‑630A versions certification ongoing. Get technical confirmation before project adoption.

Operating & Derating Conditions

Important: Recommended continuous operating current ≤75 % of fuse nominal rating under standard conditions.

Ambient Temperature Derating

Above 40 ℃ ambient temperature requires rated‑current derating according to derating curve. Below ‑5 ℃, pre‑arcing time for low overload will slightly extend.

Altitude Derating

Normal working altitude ≤2000 m. For closed‑enclosure applications at altitude 2000‑4500 m: derate rated current 2‑5 % per 1000 m elevation increase. Air insulation strength drops at high altitude, check clearance per GB/T 16935.1.

Forced Air Cooling Correction

Forced ventilation improves heat‑dissipation and raises allowable continuous operating current, refer to Kv correction curve vs wind‑speed(m/s).

Time‑Current Characteristic Curve

Covers rating 100‑630A. Curve tolerance: ±15 % on current axis. Minimum breaking current =5 × In.

Frequently Asked Questions

1: What is the minimum breaking current for GFHVT1500‑A‑59ES series?

1: Minimum breaking current equals 5 times nominal rated current(5In).

2: What does flush‑end‑contact terminal mean?

2: Flush‑end contact (Type‑A) is flat end‑face mounting with two M10 holes, designed for compact rack installation to save cabinet internal space.

3: Can GFHVT1500‑A‑59ES be used for lithium‑ion battery‑module protection?

3: Yes. It is aR‑class fast‑acting flush‑end fuse for battery‑module and compact‑BESS DC‑circuit protection. Please verify I²t coordination with your BMS.

4: Are 450‑630A models fully certified?

4: Certifications for 450‑630A are still in process. Contact EssFuse engineering for project evaluation before selection.

5: What derating shall I apply for sealed cabinet working at high altitude?

5: For sealed cabinets operating above 2000 m altitude, derate 2‑5 % per 1000 m elevation. Higher derating ratio applies for larger‑ampacity models.

6: What is suggested maximum continuous operating current?

7: Under standard ambient‑temperature conditions, continuous working current should not exceed 75 % of fuse nominal rated‑current.

Download Datasheet & Resources

📄 Download GFHVT1500‑A‑59ES Series Datasheet(PDF)GFHVT1500-A-59ES-Series.-100-630A-1500Vdc fast-acting fuse

📎 Request REACH Declaration | Request CAD Drawing | Ask Technical Support

Need fuse‑selection support? Contact our engineering team for I²t‑matching and system‑coordination advice for your compact‑energy‑storage project.