GFHVT1500‑159E 1500Vdc Fast‑Acting Fuse 1400‑3000A

GFHVT1500‑159E high‑current DC fuse,1500Vdc,1400‑3000A,250kA interrupt@L/R≤5ms. UL‑listed for large‑scale BESS & PCS DC‑side protection. Download datasheet.

20+ Years Experience

Over 20 years in electrical protection and fuse manufacturing.

 

Strict Quality Control

Rigorous testing ensures reliable product performance.

 

GFHVT1500‑159E Series 1500Vdc Fast‑Acting High‑Current Fuse 1400‑3000A

SKU Series:GFHVT1500‑159E|Voltage:1500V DC|Current Range:1400‑3000A|Interrupt:250kA@L/R≤5ms ;100kA@L/R≤15ms

Product Overview

The GFHVT1500‑159E series is heavy‑duty round‑body high‑speed DC fuse link engineered for megawatt‑scale energy‑storage systems. Rated 1500Vdc, it covers high ampere ratings 1400A‑3000A. Interrupt performance: 250kA@1500Vdc(L/R ≤5 ms), 100kA@1500Vdc(L/R ≤15 ms).

Specially designed for container‑type BESS and PCS DC‑side main‑bus protection, this UL‑listed fuse delivers superior DC arc‑quenching performance, outstanding cycling capability and high mechanical shock‑vibration resistance. It adopts multi‑M12 bolt‑on busbar mounting for high‑current power‑conducting connections.

Key Features & Benefits

  • ✅ Rated for 1500 Vdc, built for large‑scale DC energy‑storage architecture
  • ✅ High interrupt rating: 250 kA @1500Vdc (L/R ≤5 ms);100 kA @1500Vdc(L/R ≤15 ms)
  • ✅ UL Listed to UL 248‑13 standard
  • ✅ Optimized I²t characteristic for semiconductor & battery short‑circuit coordination
  • ✅ Superior cycling capability for frequent charge‑discharge working cycles
  • ✅ Heavy‑duty M12 multi‑bolt busbar mounting; torque‑specified installation
  • ✅ High shock & vibration resistance ≥20g, fits container‑level ESS cabinet
  • ✅ RoHS compliant, REACH statement available upon request

Main Electrical Specifications

ParameterSpecification
Rated Voltage1500 Vdc
Rated Current Range1400A‑3000A
Interrupting Capacity250kA@1500Vdc(L/R ≤5ms);100kA@1500Vdc(L/R ≤15ms)
MountingMulti‑M12 bolt‑on busbar connection
Recommended tightening torqueNut 35±4% N·m; set screw 5‑8 N·m
Storage Temperature-40 ℃ ~ +85 ℃
Normal Operating Ambient-5 ℃ ~ +40 ℃
Allowable Operating Temperature-40 ℃ ~ +85 ℃

Note: Recommended continuous operating current ≤75 % of fuse nominal rating under standard ambient‑temperature conditions. L/R time‑constant strongly affects DC interrupt performance; always validate circuit L/R ratio in application.

Part Numbering Explanation

Example Model: GFHVT1500‑2000A‑159E

CodeDefinition
GFManufacturer Code (GFEV)
HVHigh‑Speed / Fast‑Acting
TCeramics Body
1500Rated Voltage:1500Vdc
2000Rated Current(A)
ATerminal Type (A/B busbar connection)
159ESeries Code

Mechanical Dimensions & Installation

Multi‑M12 screw mounting interface for high‑current busbar connection. Please strictly follow torque specification during assembly.

Installation note: 5 pcs M12 socket‑head set‑screws each side. Nut tightening torque: 35±4% N·m, set‑screw torque: 5‑8 N·m. Reference standard ISO4026 / DIN913.

Full Part List Table

Part NumberFuse AmpsPre‑Arcing I²t(A²s)Max Operating I²t(A²s)Power Loss(W)RoHS
GFHVT1500‑1400A‑159E1400A8332503024000350●
GFHVT1500‑1500A‑159E1500A10780003759500370●
GFHVT1500‑1600A‑159E1600A13257005435000420●
GFHVT1500‑1800A‑159E1800A19800005750000460●
GFHVT1500‑2000A‑159E2000A25300007910000475●
GFHVT1500‑2500A‑159E2500A469650014294000520●
GFHVT1500‑3000A‑159E3000A850500025029000590●

Application Fields

  • ⚡ Container‑scale & megawatt‑level Battery Energy Storage System(BESS) main DC bus protection
  • ⚡ PCS power conversion system DC‑side short‑circuit protection
  • ⚡ Large‑capacity lithium‑ion battery rack & battery cluster protection
  • ⚡ Heavy‑duty DC industrial power equipment
  • ⚡ Main circuit fault isolation for utility‑grade energy‑storage power station

Standards & Certifications

Standard / CertificateStatus
UL 248‑13UL Listed
RoHSCompliant
REACHDeclaration available upon request

Important: DC interrupt capability depends heavily on circuit L/R time‑constant. Confirm actual system L/R before project adoption.

Operating & Derating Conditions

Important: Recommended continuous operating current ≤75 % of fuse nominal rating under standard conditions.

Ambient Temperature Derating

Above 40 ℃ ambient temperature requires rated‑current derating according to derating curve. Below ‑5 ℃, pre‑arcing time for low overload will slightly extend.

Altitude Derating

Normal working altitude ≤2000 m. For closed‑enclosure applications at altitude 2000‑4500 m: derate rated current 2‑5 % per 1000 m elevation increase. Air insulation strength drops at high altitude, check clearance per GB/T 16935.1.

Forced Air Cooling Correction

Forced ventilation improves heat‑dissipation and raises allowable continuous operating current, refer to Kv correction curve vs wind‑speed(m/s).

Characteristic Curves

Time‑Current Characteristic Curve

Covers rating range 1400‑3000A. DC interrupt performance subject to system L/R time‑constant.

Watts‑Loss Curve

Max Operating I²t Voltage Correction Factor Curve

Frequently Asked Questions

1: What is the interrupt rating of GFHVT1500‑159E?

1: 250kA@1500Vdc for L/R ≤5 ms;100kA@1500Vdc for L/R ≤15 ms. DC interrupt performance depends on circuit L/R time‑constant.

2: Can GFHVT1500‑159E be used for container‑scale megawatt BESS main DC bus?

2: Yes. It is designed for utility‑grade large‑capacity energy‑storage DC main‑bus protection. Must perform I²t coordination and L/R time‑constant verification with your BMS & PCS.

3: What are the installation torque requirements for GFHVT1500‑159E?

3: Nut tightening torque:35±4% N·m; M12 set‑screw torque:5‑8 N·m. Improper torque will cause overheating and potential safety risk.

4: What derating shall I use for sealed cabinet working at high altitude?

4: For sealed cabinets operating above 2000 m altitude, derate 2‑5 % per 1000 m elevation. Higher derating ratio applies for higher‑ampacity models.

5: What is suggested maximum continuous operating current?

5: Under standard ambient‑temperature conditions, continuous working current should not exceed 75 % of fuse nominal rated‑current.

Download Datasheet & Resources

📄 Download GFHVT1500‑159E Series Datasheet(PDF)GFHVT1500-159E-Series.-1400-3000A-1500Vdc Fast-Acting Fuse-1

📎 Request REACH Declaration | Request CAD Drawing | Ask Technical Support

Need fuse‑selection support? Contact our engineering team for I²t matching, L/R‑ratio evaluation and system‑coordination advice for your energy‑storage project.