{"id":30970,"date":"2026-09-22T23:52:35","date_gmt":"2026-09-22T23:52:35","guid":{"rendered":"https:\/\/gfevfuse.com\/?post_type=product&#038;p=30970"},"modified":"2026-10-23T03:58:16","modified_gmt":"2026-10-23T03:58:16","slug":"gfevt500-74e-500vdc-fast-acting-dc-fuse","status":"publish","type":"product","link":"https:\/\/gfevfuse.com\/pt\/gfevt500-74e-500vdc-fast-acting-dc-fuse\/","title":{"rendered":"Fus\u00edvel CC de a\u00e7\u00e3o r\u00e1pida com corpo quadrado da s\u00e9rie GFEVT500-74E, 500 Vcc, 500 A-1800 A, tamanho 3#"},"content":{"rendered":"<p>Os fus\u00edveis de a\u00e7\u00e3o r\u00e1pida de corpo quadrado da s\u00e9rie GFEVT500-74E s\u00e3o projetados para aplica\u00e7\u00f5es CC de alta pot\u00eancia. Este fus\u00edvel de prote\u00e7\u00e3o semicondutora classe aR oferece desempenho de limita\u00e7\u00e3o de corrente ultrarr\u00e1pido para condi\u00e7\u00f5es de falha CC, com constante de tempo \u2264 5 ms. Classificado em 500 Vcc e abrangendo correntes nominais de 500 A a 1800 A em encapsulamento tamanho 3#.<\/p>\n<p>Duas vers\u00f5es mec\u00e2nicas est\u00e3o dispon\u00edveis: sufixo <strong>B\u201174E<\/strong> para instala\u00e7\u00e3o horizontal aparafusada; sufixo <strong>K\u201174E<\/strong> Para montagem vertical personalizada com parafusos de fixa\u00e7\u00e3o, adaptando-se a diferentes configura\u00e7\u00f5es de barramento. O design de baixa perda de pot\u00eancia minimiza a gera\u00e7\u00e3o de calor sob carga cont\u00ednua, e a alta resist\u00eancia \u00e0 vibra\u00e7\u00e3o (\u226520 g) o torna adequado para ambientes industriais severos e sistemas m\u00f3veis de armazenamento de energia.<\/p>\n<p><a href=\"https:\/\/gfevfuse.com\/wp-content\/uploads\/2026\/09\/GFEVT500-74E-500A-1800A-500V-fast-acting-fuse.pdf\">Fus\u00edvel CC de a\u00e7\u00e3o r\u00e1pida GFEVT500\u201174E 500Vdc 500\u20111800A aR<\/a><\/p>\n<h3>\u00a0Principais especifica\u00e7\u00f5es el\u00e9tricas<\/h3>\n<table>\n<thead>\n<tr>\n<th>Item<\/th>\n<th>Especifica\u00e7\u00f5es<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Tens\u00e3o nominal<\/td>\n<td>500 V CC<\/td>\n<\/tr>\n<tr>\n<td>Corrente nominal<\/td>\n<td>500 A\u20111800 A<\/td>\n<\/tr>\n<tr>\n<td>Capacidade m\u00e1xima de ruptura<\/td>\n<td>50 kA a 500 Vdc<\/td>\n<\/tr>\n<tr>\n<td>Corrente m\u00ednima de ruptura<\/td>\n<td>\u22655\u00d7In (5In)<\/td>\n<\/tr>\n<tr>\n<td>Constante de tempo<\/td>\n<td>\u22645 ms<\/td>\n<\/tr>\n<tr>\n<td>Aula<\/td>\n<td>aR (Prote\u00e7\u00e3o de a\u00e7\u00e3o r\u00e1pida para semicondutores\/CC)<\/td>\n<\/tr>\n<tr>\n<td>Tamanho<\/td>\n<td>3# Corpo quadrado<\/td>\n<\/tr>\n<tr>\n<td>Montagem<\/td>\n<td>B-74E: Parafuso horizontal; K-74E: Parafuso de garfo vertical personalizado<\/td>\n<\/tr>\n<tr>\n<td>Padr\u00f5es<\/td>\n<td>UL 248.1\/UL 248.13; IEC 60269\u20111\/IEC 60269\u20114<\/td>\n<\/tr>\n<tr>\n<td>Conformidade<\/td>\n<td>RoHS; Declara\u00e7\u00e3o REACH dispon\u00edvel mediante solicita\u00e7\u00e3o.<\/td>\n<\/tr>\n<tr>\n<td>Corrente cont\u00ednua recomendada<\/td>\n<td>\u226475 % de classifica\u00e7\u00e3o Em<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<blockquote><p>Nota: Os modelos 1500A, 1600A e 1800A requerem confirma\u00e7\u00e3o pr\u00e9via da f\u00e1brica antes da encomenda.<\/p><\/blockquote>\n<h3>\u00a0Principais caracter\u00edsticas<\/h3>\n<ul>\n<li>Excelente desempenho na interrup\u00e7\u00e3o de falhas em corrente cont\u00ednua: extin\u00e7\u00e3o r\u00e1pida do arco em caso de curto-circuito em corrente cont\u00ednua, protegendo m\u00f3dulos de bateria e semicondutores de pot\u00eancia.<\/li>\n<li>Baixa perda de energia, melhora a efici\u00eancia geral do sistema e reduz o estresse t\u00e9rmico.<\/li>\n<li>Capacidade de ciclagem superior para ciclos frequentes de carga e descarga em sistemas de baterias.<\/li>\n<li>Alta resist\u00eancia a choques mec\u00e2nicos e vibra\u00e7\u00f5es (acelera\u00e7\u00e3o \u226520 g), adequada para equipamentos m\u00f3veis e fora da rede el\u00e9trica.<\/li>\n<li>Ampla faixa de temperatura de opera\u00e7\u00e3o: opera\u00e7\u00e3o normal -5\u2103 a 40\u2103; permitida -40\u2103 a 85\u2103. Redu\u00e7\u00e3o de pot\u00eancia necess\u00e1ria acima de 40\u2103.<\/li>\n<li>Duas configura\u00e7\u00f5es de montagem para um projeto flex\u00edvel de layout de gabinete e barramento.<\/li>\n<\/ul>\n<h3>Aplica\u00e7\u00f5es t\u00edpicas<\/h3>\n<ol>\n<li>Prote\u00e7\u00e3o do barramento CC do sistema de armazenamento de energia (ESS)<\/li>\n<li>Prote\u00e7\u00e3o contra curto-circuito no circuito principal para baterias de alta tens\u00e3o.<\/li>\n<li>Prote\u00e7\u00e3o de curto-circuito de reserva para contatores e rel\u00e9s CC<\/li>\n<li>Fonte de alimenta\u00e7\u00e3o CC de alta pot\u00eancia e prote\u00e7\u00e3o de link CC industrial<\/li>\n<\/ol>\n<h3>\u00a0Condi\u00e7\u00f5es de opera\u00e7\u00e3o e orienta\u00e7\u00f5es sobre redu\u00e7\u00e3o de pot\u00eancia<\/h3>\n<ul>\n<li><strong>Temperatura ambiente<\/strong>Reduza a corrente nominal atrav\u00e9s do fator Kt quando a temperatura ambiente exceder 40\u00b0C. Abaixo de -5\u00b0C, o tempo de pr\u00e9-arco aumenta ligeiramente.<\/li>\n<li><strong>Altitude<\/strong>Em altitudes de at\u00e9 2000 m, nenhuma corre\u00e7\u00e3o \u00e9 necess\u00e1ria. Para gabinetes fechados acima de 2000 m: reduzir a pot\u00eancia nominal em 2 a 5 % por cada aumento de 1000 m. A instala\u00e7\u00e3o ao ar livre normalmente ignora a influ\u00eancia da altitude. As folgas de isolamento devem estar em conformidade com a norma GB\/T 16935.1.<\/li>\n<li><strong>Dimensionamento de condutores<\/strong>Selecione a se\u00e7\u00e3o transversal do cabo de cobre\/barra de distribui\u00e7\u00e3o conforme a folha de dados; densidade de corrente recomendada de 1250 a 1800 A: 1,0 a 1,4 A\/mm\u00b2.<\/li>\n<li><strong>Resfriamento for\u00e7ado<\/strong>Velocidades de ar mais elevadas aumentam a corrente nominal admiss\u00edvel; consulte a curva de resfriamento Kv.<\/li>\n<li><strong>Instala\u00e7\u00e3o<\/strong>Instale na horizontal, vertical ou inclinada. Evite a substitui\u00e7\u00e3o do fus\u00edvel temporizado, a menos que a chave de interrup\u00e7\u00e3o de carga esteja acionada.<\/li>\n<\/ul>\n<h3>\u00a0Lista de modelos (parcial)<\/h3>\n<table>\n<thead>\n<tr>\n<th>N\u00ba da pe\u00e7a.<\/th>\n<th>Corrente nominal<\/th>\n<th>Tipo de montagem<\/th>\n<th>Perda de pot\u00eancia (carga 100%, W)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>GFEVT500\u2011500B\u201174E<\/td>\n<td>500A<\/td>\n<td>Parafuso horizontal B-74E<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<td>GFEVT500\u2011800B\u201174E<\/td>\n<td>800A<\/td>\n<td>Parafuso horizontal B-74E<\/td>\n<td>130<\/td>\n<\/tr>\n<tr>\n<td>GFEVT500\u20111000B\u201174E<\/td>\n<td>1000A<\/td>\n<td>Parafuso horizontal B-74E<\/td>\n<td>145<\/td>\n<\/tr>\n<tr>\n<td>GFEVT500\u20111250K\u201174E<\/td>\n<td>1250A<\/td>\n<td>Garfo vertical personalizado K-74E<\/td>\n<td>180<\/td>\n<\/tr>\n<tr>\n<td>GFEVT500\u20111800K\u201174E*<\/td>\n<td>1800A<\/td>\n<td>Garfo vertical personalizado K-74E<\/td>\n<td>260<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>*\u00c9 necess\u00e1ria comunica\u00e7\u00e3o t\u00e9cnica pr\u00e9-venda para os modelos de alta corrente marcados com asterisco.<\/p>\n<h3>\u00a0Desenhos e curvas caracter\u00edsticas<\/h3>\n<ul>\n<li>Desenhos dimensionais mec\u00e2nicos para montagem horizontal da vers\u00e3o B e montagem vertical da vers\u00e3o K.<\/li>\n<li>Curva caracter\u00edstica tempo-corrente: toler\u00e2ncia de corrente \u00b115 %. Corrente m\u00ednima de interrup\u00e7\u00e3o 5In.<\/li>\n<li>Curvas de redu\u00e7\u00e3o de pot\u00eancia: redu\u00e7\u00e3o de pot\u00eancia em fun\u00e7\u00e3o da temperatura ambiente (Kt), corre\u00e7\u00e3o de altitude (Ka), curva de resfriamento por ar for\u00e7ado (Kv).<\/li>\n<\/ul>\n<h3>\u00a0Informa\u00e7\u00f5es para encomenda<\/h3>\n<ul>\n<li>Sufixo <strong>B\u201174E<\/strong>Montagem padr\u00e3o com parafuso longo horizontal.<\/li>\n<li>Sufixo <strong>K\u201174E<\/strong>: montagem personalizada com parafuso vertical tipo garfo.<\/li>\n<li>Documento de conformidade com o REACH dispon\u00edvel mediante solicita\u00e7\u00e3o. Todas as unidades est\u00e3o em conformidade com a RoHS.<\/li>\n<li>Correntes nominais elevadas (1500-1800 A) requerem confirma\u00e7\u00e3o t\u00e9cnica pr\u00e9via \u00e0 encomenda.<\/li>\n<\/ul>\n<blockquote><p>Chamada \u00e0 a\u00e7\u00e3o: Baixe a ficha t\u00e9cnica completa, envie uma solicita\u00e7\u00e3o de or\u00e7amento e verifique a disponibilidade de amostras.<\/p><\/blockquote>\n<h2>Perguntas frequentes<\/h2>\n<h3>Qual \u00e9 a corrente m\u00ednima de interrup\u00e7\u00e3o do fus\u00edvel GFEVT500\u201174E?<\/h3>\n<p>Corrente m\u00ednima de interrup\u00e7\u00e3o \u22655 vezes a corrente nominal (5In), constante de tempo \u22645 ms para elimina\u00e7\u00e3o r\u00e1pida de falhas CC.<\/p>\n<h3>Qual a diferen\u00e7a entre os sufixos B\u201174E e K\u201174E?<\/h3>\n<p>B-74E: montagem horizontal padr\u00e3o com parafusos longos; K-74E: montagem vertical personalizada com parafusos de fixa\u00e7\u00e3o. O desempenho el\u00e9trico permanece id\u00eantico.<\/p>\n<h3>Preciso reduzir a capacidade nominal deste fus\u00edvel em altas temperaturas ambientes?<\/h3>\n<p>Reduza a corrente de opera\u00e7\u00e3o pelo fator Kt quando a temperatura ambiente for superior a 40 \u00b0C. Abaixo de 5 \u00b0C, o tempo de pr\u00e9-arco aumenta ligeiramente, n\u00e3o sendo geralmente necess\u00e1rio usar um fus\u00edvel de tamanho maior.<\/p>\n<h3>O GFEVT500\u201174E pode ser usado para prote\u00e7\u00e3o do circuito principal de baterias de \u00edon-l\u00edtio?<\/h3>\n<p>Sim, trata-se de um fus\u00edvel CC de a\u00e7\u00e3o r\u00e1pida classe R, especialmente projetado para prote\u00e7\u00e3o contra curto-circuito em baterias e sistemas de armazenamento de energia. Corrente operacional cont\u00ednua recomendada \u2264 75 % da corrente nominal do fus\u00edvel.<\/p>\n<h3>Que corre\u00e7\u00e3o deve ser aplicada para instala\u00e7\u00f5es em grandes altitudes?<\/h3>\n<p>Nenhuma corre\u00e7\u00e3o abaixo de 2000 m. Para gabinetes fechados entre 2000 e 4500 m, reduza a corrente nominal em 2 a 5 % por 1000 m de altitude. Os espa\u00e7amentos de isolamento devem seguir a norma IEC\/GB\/T 16935.1.<\/p>","protected":false},"excerpt":{"rendered":"<p>Fus\u00edvel CC quadrado GFEVT500-74E, 500 Vcc, capacidade de interrup\u00e7\u00e3o de 50 kA, classe aR para prote\u00e7\u00e3o de sistemas de armazenamento de energia e baterias. Em conformidade com as normas UL248.13 e IEC60269-4. Solicite a ficha t\u00e9cnica e um or\u00e7amento.<\/p>","protected":false},"featured_media":30981,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[93],"product_tag":[],"class_list":["post-30970","product","type-product","status-publish","has-post-thumbnail","product_cat-square-high-speed-fuse","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/gfevfuse.com\/pt\/wp-json\/wp\/v2\/product\/30970","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gfevfuse.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/gfevfuse.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/gfevfuse.com\/pt\/wp-json\/wp\/v2\/comments?post=30970"}],"version-history":[{"count":3,"href":"https:\/\/gfevfuse.com\/pt\/wp-json\/wp\/v2\/product\/30970\/revisions"}],"predecessor-version":[{"id":32392,"href":"https:\/\/gfevfuse.com\/pt\/wp-json\/wp\/v2\/product\/30970\/revisions\/32392"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gfevfuse.com\/pt\/wp-json\/wp\/v2\/media\/30981"}],"wp:attachment":[{"href":"https:\/\/gfevfuse.com\/pt\/wp-json\/wp\/v2\/media?parent=30970"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/gfevfuse.com\/pt\/wp-json\/wp\/v2\/product_brand?post=30970"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/gfevfuse.com\/pt\/wp-json\/wp\/v2\/product_cat?post=30970"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/gfevfuse.com\/pt\/wp-json\/wp\/v2\/product_tag?post=30970"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}