{"id":31193,"date":"2026-09-26T02:03:50","date_gmt":"2026-09-26T02:03:50","guid":{"rendered":"https:\/\/gfevfuse.com\/?post_type=product&#038;p=31193"},"modified":"2026-10-24T00:34:55","modified_gmt":"2026-10-24T00:34:55","slug":"gfhvt1500-159e-1500vdc-fast-acting-high-current-fuse-1400-3000a","status":"publish","type":"product","link":"https:\/\/gfevfuse.com\/fr\/gfhvt1500-159e-1500vdc-fast-acting-high-current-fuse-1400-3000a\/","title":{"rendered":"Fusible \u00e0 action rapide GFHVT1500\u2011159E 1500 Vcc 1400\u20113000 A"},"content":{"rendered":"<h1>Fusible \u00e0 action rapide haute intensit\u00e9 1\u00a0400 \u00e0 3\u00a0000\u00a0A, s\u00e9rie GFHVT1500-159E, 1\u00a0500\u00a0Vcc<\/h1>\n<blockquote><p>R\u00e9f\u00e9rence s\u00e9rie\u00a0: GFHVT1500\u2011159E | Tension\u00a0: 1\u00a0500\u00a0V CC | Courant\u00a0: 1\u00a0400\u20113\u00a0000\u00a0A | Pouvoir de coupure\u00a0: 250\u00a0kA \u00e0 L\/R \u2264 5\u00a0ms\u00a0; 100\u00a0kA \u00e0 L\/R \u2264 15\u00a0ms<\/p><\/blockquote>\n<h2>Pr\u00e9sentation du produit<\/h2>\n<p>Le <strong>S\u00e9rie GFHVT1500\u2011159E<\/strong> Il s&#039;agit d&#039;un fusible CC haute vitesse \u00e0 corps rond robuste, con\u00e7u pour les syst\u00e8mes de stockage d&#039;\u00e9nergie \u00e0 l&#039;\u00e9chelle du m\u00e9gawatt. <strong>1500 Vcc<\/strong>, il couvre les valeurs d&#039;amp\u00e9rage \u00e9lev\u00e9es <strong>1400A\u20113000A<\/strong>. Interrompre les performances\u00a0: <strong>250 kA \u00e0 1500 Vcc (L\/R \u2264 5 ms), 100 kA \u00e0 1500 Vcc (L\/R \u2264 15 ms)<\/strong>.<\/p>\n<p>Sp\u00e9cialement con\u00e7u pour la protection du bus principal CC des syst\u00e8mes de stockage d&#039;\u00e9nergie par batterie (BESS) et des syst\u00e8mes de commutation (PCS) de type conteneur, ce fusible homologu\u00e9 UL offre des performances sup\u00e9rieures d&#039;extinction d&#039;arc CC, une excellente capacit\u00e9 de cyclage et une haute r\u00e9sistance aux chocs et vibrations m\u00e9caniques. Il est \u00e9quip\u00e9 d&#039;un syst\u00e8me de fixation par boulonnage multiple M12 sur barre omnibus pour les connexions conductrices de courant \u00e9lev\u00e9.<\/p>\n<h2>Principales caract\u00e9ristiques et avantages<\/h2>\n<ul>\n<li>\u2705 \u00c9valu\u00e9 pour <strong>1500 Vcc<\/strong>, con\u00e7u pour une architecture de stockage d&#039;\u00e9nergie CC \u00e0 grande \u00e9chelle<\/li>\n<li>\u2705 Taux d&#039;interruption \u00e9lev\u00e9\u00a0: <strong>250 kA \u00e0 1500 Vcc (L\/R \u2264 5 ms) ; 100 kA \u00e0 1500 Vcc (L\/R \u2264 15 ms)<\/strong><\/li>\n<li>\u2705 Homologu\u00e9 UL selon la norme UL 248-13<\/li>\n<li>\u2705 Caract\u00e9ristique I\u00b2t optimis\u00e9e pour la coordination des courts-circuits entre semi-conducteurs et batteries<\/li>\n<li>\u2705 Capacit\u00e9 de cyclage sup\u00e9rieure pour les cycles de charge-d\u00e9charge fr\u00e9quents<\/li>\n<li>\u2705 Fixation robuste de la barre omnibus par plusieurs boulons M12\u00a0; installation avec couple de serrage sp\u00e9cifi\u00e9<\/li>\n<li>\u2705 Haute r\u00e9sistance aux chocs et aux vibrations \u2265 20 g, compatible avec les armoires ESS de niveau conteneur<\/li>\n<li>\u2705 Conforme \u00e0 la directive RoHS, d\u00e9claration REACH disponible sur demande<\/li>\n<\/ul>\n<h2>Principales caract\u00e9ristiques \u00e9lectriques<\/h2>\n<table>\n<thead>\n<tr>\n<th>Param\u00e8tre<\/th>\n<th>Sp\u00e9cification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Tension nominale<\/td>\n<td>1500 Vcc<\/td>\n<\/tr>\n<tr>\n<td>Plage de courant nominal<\/td>\n<td>1400A\u20113000A<\/td>\n<\/tr>\n<tr>\n<td>Capacit\u00e9 d&#039;interruption<\/td>\n<td>250 kA \u00e0 1500 Vcc (L\/R \u2264 5 ms) ; 100 kA \u00e0 1500 Vcc (L\/R \u2264 15 ms)<\/td>\n<\/tr>\n<tr>\n<td>Montage<\/td>\n<td>Raccordement de barre omnibus \u00e0 boulonner Multi-M12<\/td>\n<\/tr>\n<tr>\n<td>Couple de serrage recommand\u00e9<\/td>\n<td>\u00c9crou 35\u00b14% N\u00b7m\u00a0; vis de blocage 5\u20118 N\u00b7m<\/td>\n<\/tr>\n<tr>\n<td>Temp\u00e9rature de stockage<\/td>\n<td>-40 \u2103 ~ +85 \u2103<\/td>\n<\/tr>\n<tr>\n<td>Environnement de fonctionnement normal<\/td>\n<td>-5 \u00b0C ~ +40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temp\u00e9rature de fonctionnement admissible<\/td>\n<td>-40 \u2103 ~ +85 \u2103<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<blockquote><p>Remarque\u00a0: Courant de fonctionnement continu recommand\u00e9 \u2264 75\u00a0A % du calibre nominal du fusible dans des conditions de temp\u00e9rature ambiante standard. La constante de temps L\/R influe fortement sur les performances de coupure CC\u00a0; toujours v\u00e9rifier le rapport L\/R du circuit dans l\u2019application.<\/p><\/blockquote>\n<h2>Explication de la num\u00e9rotation des pi\u00e8ces<\/h2>\n<p>Exemple de mod\u00e8le\u00a0: <code>GFHVT1500\u20112000A\u2011159E<\/code><\/p>\n<table>\n<thead>\n<tr>\n<th>Code<\/th>\n<th>D\u00e9finition<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>GF<\/td>\n<td>Code du fabricant (GFEV)<\/td>\n<\/tr>\n<tr>\n<td>HV<\/td>\n<td>Haute vitesse \/ Action rapide<\/td>\n<\/tr>\n<tr>\n<td>T<\/td>\n<td>Corps en c\u00e9ramique<\/td>\n<\/tr>\n<tr>\n<td>1500<\/td>\n<td>Tension nominale\u00a0: 1\u00a0500\u00a0Vcc<\/td>\n<\/tr>\n<tr>\n<td>2000<\/td>\n<td>Courant nominal (A)<\/td>\n<\/tr>\n<tr>\n<td>A<\/td>\n<td>Type de terminal (connexion par barre omnibus A\/B)<\/td>\n<\/tr>\n<tr>\n<td>159E<\/td>\n<td>Code de s\u00e9rie<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimensions m\u00e9caniques et installation<\/h2>\n<blockquote><p>Interface de montage \u00e0 vis multiples M12 pour le raccordement de barres omnibus haute intensit\u00e9. Veuillez respecter scrupuleusement les couples de serrage sp\u00e9cifi\u00e9s lors du montage.<\/p><\/blockquote>\n<blockquote><p>Note d&#039;installation\u00a0: 5 vis \u00e0 t\u00eate creuse M12 de chaque c\u00f4t\u00e9. Couple de serrage des \u00e9crous\u00a0: <strong>35\u00b14% N\u00b7m<\/strong>, couple de serrage de la vis de blocage\u00a0: <strong>5\u20118 N\u00b7m<\/strong>. Norme de r\u00e9f\u00e9rence ISO4026 \/ DIN913.<\/p><\/blockquote>\n<h3>Tableau complet des pi\u00e8ces<\/h3>\n<table>\n<thead>\n<tr>\n<th>Num\u00e9ro de pi\u00e8ce<\/th>\n<th>Amp\u00e8res du fusible<\/th>\n<th>Pr\u00e9-arc I\u00b2t(A\u00b2s)<\/th>\n<th>I\u00b2t de fonctionnement maximal (A\u00b2s)<\/th>\n<th>Perte de puissance (W)<\/th>\n<th>RoHS<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>GFHVT1500\u20111400A\u2011159E<\/td>\n<td>1400A<\/td>\n<td>833250<\/td>\n<td>3024000<\/td>\n<td>350<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>GFHVT1500\u20111500A\u2011159E<\/td>\n<td>1500A<\/td>\n<td>1078000<\/td>\n<td>3759500<\/td>\n<td>370<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>GFHVT1500\u20111600A\u2011159E<\/td>\n<td>1600A<\/td>\n<td>1325700<\/td>\n<td>5435000<\/td>\n<td>420<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>GFHVT1500\u20111800A\u2011159E<\/td>\n<td>1800A<\/td>\n<td>1980000<\/td>\n<td>5750000<\/td>\n<td>460<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>GFHVT1500\u20112000A\u2011159E<\/td>\n<td>2000A<\/td>\n<td>2530000<\/td>\n<td>7910000<\/td>\n<td>475<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>GFHVT1500\u20112500A\u2011159E<\/td>\n<td>2500A<\/td>\n<td>4696500<\/td>\n<td>14294000<\/td>\n<td>520<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>GFHVT1500\u20113000A\u2011159E<\/td>\n<td>3000A<\/td>\n<td>8505000<\/td>\n<td>25029000<\/td>\n<td>590<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Domaines d&#039;application<\/h2>\n<ul>\n<li>\u26a1 <strong>protection du bus CC principal des syst\u00e8mes de stockage d&#039;\u00e9nergie par batterie (BESS) \u00e0 l&#039;\u00e9chelle du conteneur et du m\u00e9gawatt<\/strong><\/li>\n<li>\u26a1 Syst\u00e8me de conversion de puissance PCS avec protection contre les courts-circuits c\u00f4t\u00e9 CC<\/li>\n<li>\u26a1 Protection du rack et du bloc de batteries lithium-ion haute capacit\u00e9<\/li>\n<li>\u26a1 \u00c9quipements d&#039;alimentation industrielle CC robustes<\/li>\n<li>\u26a1 Isolation des d\u00e9fauts du circuit principal pour une centrale de stockage d&#039;\u00e9nergie de qualit\u00e9 industrielle<\/li>\n<\/ul>\n<h2>Normes et certifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Norme \/ Certificat<\/th>\n<th>Statut<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>UL 248\u201113<\/td>\n<td>Homologu\u00e9 UL<\/td>\n<\/tr>\n<tr>\n<td>RoHS<\/td>\n<td>Conforme<\/td>\n<\/tr>\n<tr>\n<td>ATTEINDRE<\/td>\n<td>D\u00e9claration disponible sur demande<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<blockquote><p>Important\u00a0: La capacit\u00e9 d\u2019interruption CC d\u00e9pend fortement de la constante de temps L\/R du circuit. V\u00e9rifiez la valeur L\/R r\u00e9elle du syst\u00e8me avant l\u2019adoption du projet.<\/p><\/blockquote>\n<h2>Conditions de fonctionnement et de d\u00e9classement<\/h2>\n<blockquote><p>Important : Courant de fonctionnement continu recommand\u00e9 \u226475 % du calibre nominal du fusible dans des conditions standard.<\/p><\/blockquote>\n<h3>D\u00e9classement en fonction de la temp\u00e9rature ambiante<\/h3>\n<p>Au-dessus de 40 \u00b0C, la temp\u00e9rature ambiante n\u00e9cessite une r\u00e9duction du courant nominal conform\u00e9ment \u00e0 la courbe de r\u00e9duction. En dessous de -5 \u00b0C, le temps de pr\u00e9-amor\u00e7age pour une faible surcharge sera l\u00e9g\u00e8rement prolong\u00e9.<\/p>\n<h3>D\u00e9classement en altitude<\/h3>\n<p>Altitude de fonctionnement normale \u2264 2\u00a0000 m. Pour les applications en enceinte ferm\u00e9e \u00e0 une altitude de 2\u00a0000 \u00e0 4\u00a0500 m\u00a0: r\u00e9duire le courant nominal. <strong>2 \u00e0 5 TP3T par tranche de 1\u00a0000 m d\u2019altitude<\/strong>. La r\u00e9sistance de l&#039;isolation \u00e0 l&#039;air diminue en haute altitude, v\u00e9rifiez le d\u00e9gagement conform\u00e9ment \u00e0 la norme GB\/T 16935.1.<\/p>\n<h3>Correction du refroidissement par air puls\u00e9<\/h3>\n<p>La ventilation forc\u00e9e am\u00e9liore la dissipation de chaleur et augmente le courant de fonctionnement continu admissible, voir la courbe de correction Kv en fonction de la vitesse du vent (m\/s).<\/p>\n<h2>Courbes caract\u00e9ristiques<\/h2>\n<h3>Courbe caract\u00e9ristique temps-courant<\/h3>\n<p>Couvre la plage de valeurs nominales de 1400 \u00e0 3000 A. Les performances de coupure CC d\u00e9pendent de la constante de temps L\/R du syst\u00e8me.<\/p>\n<h3>Courbe de perte de Watts<\/h3>\n<h3>Courbe du facteur de correction de tension I\u00b2t de fonctionnement maximal<\/h3>\n<h2>Foire aux questions<\/h2>\n<p><strong>1 : Quel est le pouvoir de coupure du GFHVT1500\u2011159E ?<\/strong><\/p>\n<p>1 : 250 kA \u00e0 1500 Vcc pour L\/R \u2264 5 ms ; 100 kA \u00e0 1500 Vcc pour L\/R \u2264 15 ms. Les performances d&#039;interruption CC d\u00e9pendent de la constante de temps L\/R du circuit.<\/p>\n<p><strong>2 : Le GFHVT1500\u2011159E peut-il \u00eatre utilis\u00e9 pour le bus CC principal d&#039;un syst\u00e8me BESS de m\u00e9gawatt \u00e0 l&#039;\u00e9chelle d&#039;un conteneur ?<\/strong><\/p>\n<p>2\u00a0: Oui. Il est con\u00e7u pour la protection du bus principal CC des syst\u00e8mes de stockage d\u2019\u00e9nergie de grande capacit\u00e9 de qualit\u00e9 industrielle. Une coordination I\u00b2t et une v\u00e9rification de la constante de temps L\/R doivent \u00eatre effectu\u00e9es avec votre syst\u00e8me de gestion technique du b\u00e2timent (GTB) et votre syst\u00e8me de contr\u00f4le de puissance (PCS).<\/p>\n<p><strong>3 : Quelles sont les exigences de couple d&#039;installation pour GFHVT1500\u2011159E ?<\/strong><\/p>\n<p>3 : Couple de serrage de l&#039;\u00e9crou : 35 \u00b1 41 N\u00b7m ; couple de serrage de la vis de blocage M12 : 5 \u00e0 8 N\u00b7m. Un couple incorrect peut entra\u00eener une surchauffe et un risque potentiel pour la s\u00e9curit\u00e9.<\/p>\n<p><strong>4 : Quel coefficient de r\u00e9duction dois-je utiliser pour une armoire \u00e9tanche fonctionnant en haute altitude ?<\/strong><\/p>\n<p>4\u00a0: Pour les armoires \u00e9tanches fonctionnant \u00e0 une altitude sup\u00e9rieure \u00e0 2\u00a0000\u00a0m, r\u00e9duire la puissance de 2 \u00e0 5\u00a0TP3T par tranche de 1\u00a0000\u00a0m d\u2019altitude. Un coefficient de r\u00e9duction plus \u00e9lev\u00e9 s\u2019applique aux mod\u00e8les \u00e0 amp\u00e9rage plus \u00e9lev\u00e9.<\/p>\n<p><strong>5 : Quel est le courant de fonctionnement continu maximal sugg\u00e9r\u00e9 ?<\/strong><\/p>\n<p>5 : Dans des conditions de temp\u00e9rature ambiante standard, le courant de fonctionnement continu ne doit pas d\u00e9passer 75 % du courant nominal du fusible.<\/p>\n<h2>T\u00e9l\u00e9charger la fiche technique et les ressources<\/h2>\n<p>\ud83d\udcc4 <strong>T\u00e9l\u00e9charger la fiche technique de la s\u00e9rie GFHVT1500\u2011159E (PDF)<a href=\"https:\/\/gfevfuse.com\/wp-content\/uploads\/2026\/09\/GFHVT1500-159E-Series.-1400-3000A-1500Vdc-Fast-Acting-Fuse-1.pdf\">Fusible \u00e0 action rapide GFHVT1500-159E-S\u00e9rie - 1400-3000A-1500Vcc - 1<\/a><\/strong><\/p>\n<p>\ud83d\udcce Demander une d\u00e9claration REACH | Demander un dessin CAO | Contacter l&#039;assistance technique<\/p>\n<blockquote><p>Besoin d&#039;aide pour le choix des fusibles\u00a0? Contactez notre \u00e9quipe d&#039;ing\u00e9nieurs pour obtenir des conseils sur l&#039;adaptation du courant I\u00b2t, l&#039;\u00e9valuation du rapport L\/R et la coordination du syst\u00e8me pour votre projet de stockage d&#039;\u00e9nergie.<\/p><\/blockquote>","protected":false},"excerpt":{"rendered":"<p>Fusible CC haute intensit\u00e9 GFHVT1500-159E, 1500 Vcc, 1400-3000 A, coupure de 250 kA \u00e0 L\/R \u2264 5 ms. Homologu\u00e9 UL pour la protection c\u00f4t\u00e9 CC des syst\u00e8mes de stockage d&#039;\u00e9nergie par batterie (BESS) et des syst\u00e8mes de commutation par onduleur (PCS) de grande envergure. T\u00e9l\u00e9charger la fiche technique.<\/p>","protected":false},"featured_media":31194,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[93],"product_tag":[],"class_list":["post-31193","product","type-product","status-publish","has-post-thumbnail","product_cat-square-high-speed-fuse","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/product\/31193","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/comments?post=31193"}],"version-history":[{"count":3,"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/product\/31193\/revisions"}],"predecessor-version":[{"id":32676,"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/product\/31193\/revisions\/32676"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/media\/31194"}],"wp:attachment":[{"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/media?parent=31193"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/product_brand?post=31193"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/product_cat?post=31193"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/product_tag?post=31193"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}