{"id":31176,"date":"2026-09-25T23:33:53","date_gmt":"2026-09-25T23:33:53","guid":{"rendered":"https:\/\/gfevfuse.com\/?post_type=product&#038;p=31176"},"modified":"2026-10-24T00:37:21","modified_gmt":"2026-10-24T00:37:21","slug":"gfhvt1500-74e-1500vdc-fast-acting-square-body-fuse-100-1250a","status":"publish","type":"product","link":"https:\/\/gfevfuse.com\/fr\/gfhvt1500-74e-1500vdc-fast-acting-square-body-fuse-100-1250a\/","title":{"rendered":"Fusible \u00e0 action rapide GFHVT1500\u201174E 1500 Vcc 100\u20111250 A 250 kA"},"content":{"rendered":"<h1>Fusible \u00e0 action rapide \u00e0 corps carr\u00e9 s\u00e9rie GFHVT1500-74E, 1500 Vcc, 100-1250 A<\/h1>\n<blockquote><p>R\u00e9f\u00e9rence : GFHVT1500-74E | Classe de fusible : aR | Tension : 1500 V CC | Plage de courant : 100-1250 A | Pouvoir de coupure maximal : 250 kA \u00e0 1500 V CC<\/p><\/blockquote>\n<h2>Pr\u00e9sentation du produit<\/h2>\n<p>Le <strong>S\u00e9rie GFHVT1500\u201174E<\/strong> Il s&#039;agit de fusibles aR \u00e0 corps carr\u00e9 et \u00e0 action rapide, sp\u00e9cialement con\u00e7us pour les circuits CC haute \u00e9nergie. Valeur nominale\u00a0: <strong>1500 Vcc<\/strong>, ce fusible CC \u00e0 courant \u00e9lev\u00e9 couvre des valeurs nominales d&#039;amp\u00e9rage de <strong>100 A \u00e0 1250 A<\/strong>, avec une capacit\u00e9 d&#039;interruption maximale allant jusqu&#039;\u00e0 <strong>250 kA \u00e0 1500 Vcc<\/strong> et courant de coupure minimum \u22655\u00d7In.<\/p>\n<p>Con\u00e7u pour les syst\u00e8mes de stockage d&#039;\u00e9nergie et les syst\u00e8mes aliment\u00e9s par batterie, il offre des performances exceptionnelles en mati\u00e8re d&#039;\u00e9limination des d\u00e9fauts CC, une faible perte de puissance, une grande endurance en cyclage et une forte r\u00e9sistance aux vibrations. Trois versions de connexion (B boulonn\u00e9e, U \u00e0 fourche DIN, K \u00e0 fourche personnalis\u00e9e) r\u00e9pondent \u00e0 diverses exigences d&#039;installation en armoire.<\/p>\n<h2>Principales caract\u00e9ristiques et avantages<\/h2>\n<ul>\n<li>\u2705 \u00c9valu\u00e9 pour <strong>1500 V CC<\/strong>, r\u00e9duit le co\u00fbt des conducteurs et am\u00e9liore l&#039;efficacit\u00e9 globale du syst\u00e8me<\/li>\n<li>\u2705 R\u00e9ponse rapide : ouverture jusqu&#039;\u00e0 10 fois plus rapide en cas de courant de d\u00e9faut \u00e9lev\u00e9 pour une protection fiable des composants<\/li>\n<li>\u2705 Classe <strong>fusible de protection pour semi-conducteurs aR<\/strong>, constante de temps \u22645 ms<\/li>\n<li>\u2705 Capacit\u00e9 de coupure \u00e9lev\u00e9e\u00a0: <strong>250 kA \u00e0 1500 Vcc<\/strong>, courant de coupure minimal \u2265 5 In<\/li>\n<li>\u2705 Faible perte de puissance, capacit\u00e9 de cyclage sup\u00e9rieure<\/li>\n<li>\u2705 Large tol\u00e9rance aux temp\u00e9ratures, excellentes performances anti-choc et anti-vibrations (r\u00e9sistance aux vibrations \u2265 20 g)<\/li>\n<li>\u2705 Trois options de fixation\u00a0: B boulonn\u00e9e, U fixation DIN sur fourche, K fixation sur fourche personnalis\u00e9e<\/li>\n<li>\u2705 Conforme \u00e0 la directive RoHS, d\u00e9claration REACH disponible sur demande<\/li>\n<li>\u2705 Conforme aux normes UL 248.1 \/ UL 248.13, IEC 60269\u20111 \/ IEC 60269\u20114<\/li>\n<\/ul>\n<h2>Principales caract\u00e9ristiques \u00e9lectriques<\/h2>\n<table>\n<thead>\n<tr>\n<th>Param\u00e8tre<\/th>\n<th>Sp\u00e9cification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Tension nominale<\/td>\n<td>1500 Vcc<\/td>\n<\/tr>\n<tr>\n<td>Plage de courant nominal<\/td>\n<td>100 A - 1250 A<\/td>\n<\/tr>\n<tr>\n<td>Classe de fusible<\/td>\n<td>aR \u00e0 action rapide<\/td>\n<\/tr>\n<tr>\n<td>Capacit\u00e9 d&#039;interruption maximale<\/td>\n<td>250 kA \u00e0 1500 Vcc<\/td>\n<\/tr>\n<tr>\n<td>Courant de coupure minimal<\/td>\n<td>\u22655\u00d7Dans<\/td>\n<\/tr>\n<tr>\n<td>Constante de temps<\/td>\n<td>\u22645 ms<\/td>\n<\/tr>\n<tr>\n<td>Types de connexion<\/td>\n<td>B (Boulonn\u00e9), U (Fourche DIN), K (Fourche personnalis\u00e9e)<\/td>\n<\/tr>\n<tr>\n<td>Temp\u00e9rature de stockage<\/td>\n<td>-40 \u00b0C ~ +120 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Environnement de fonctionnement normal<\/td>\n<td>-5 \u00b0C ~ +40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temp\u00e9rature de fonctionnement admissible<\/td>\n<td>-40 \u2103 ~ +85 \u2103<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<blockquote><p>Remarque : Les valeurs nominales sup\u00e9rieures \u00e0 800 A (900 \u00e0 1250 A) sont soumises \u00e0 confirmation de l&#039;application ; contactez l&#039;usine pour obtenir une assistance technique avant de commander des mod\u00e8les 1250 A.<\/p><\/blockquote>\n<h2>Explication de la num\u00e9rotation des pi\u00e8ces<\/h2>\n<p>Exemple de mod\u00e8le\u00a0: <code>GFHVT1500\u2011400B\u201174E<\/code><\/p>\n<table>\n<thead>\n<tr>\n<th>Code<\/th>\n<th>D\u00e9finition<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>GF<\/td>\n<td>Code du fabricant (GFEV)<\/td>\n<\/tr>\n<tr>\n<td>HV<\/td>\n<td>Haute vitesse \/ Action rapide<\/td>\n<\/tr>\n<tr>\n<td>T<\/td>\n<td>Corps en c\u00e9ramique<\/td>\n<\/tr>\n<tr>\n<td>1500<\/td>\n<td>Tension nominale\u00a0: 1\u00a0500\u00a0Vcc<\/td>\n<\/tr>\n<tr>\n<td>400<\/td>\n<td>Courant nominal (A)<\/td>\n<\/tr>\n<tr>\n<td>B<\/td>\n<td>Type de connexion\u00a0: B \/ U \/ K<\/td>\n<\/tr>\n<tr>\n<td>74E<\/td>\n<td>Code de s\u00e9rie<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Types de connexion et dimensions m\u00e9caniques<\/h2>\n<h3>Type B : Assemblage boulonn\u00e9 (xxxB-74E)<\/h3>\n<p>Montage horizontal par boulon \u00e0 barre longue, bornes \u00e0 boulon robustes pour application en armoire \u00e0 courant \u00e9lev\u00e9.<\/p>\n<h3>Type U : Connexion \u00e0 fourche DIN (xxxU-74E)<\/h3>\n<p>Bornes \u00e0 lames de type fourche DIN standard, installation horizontale.<\/p>\n<h3>Type K : Connexion de fourche personnalis\u00e9e (xxxK-74E)<\/h3>\n<p>Terminal \u00e0 fourche sur mesure pour montage vertical, adaptation m\u00e9canique sp\u00e9cifique au projet.<\/p>\n<h3>Tableau complet des pi\u00e8ces<\/h3>\n<table>\n<thead>\n<tr>\n<th>Type de connexion<\/th>\n<th>Num\u00e9ro de pi\u00e8ce<\/th>\n<th>Amp\u00e8res du fusible<\/th>\n<th>Fusion des A\u00b2s<\/th>\n<th>\u00c9limination des A\u00b2s<\/th>\n<th>Perte de puissance 80%In(W)<\/th>\n<th>Perte de puissance 100%In(W)<\/th>\n<th>RoHS<\/th>\n<th>ATTEINDRE<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Boulonn\u00e9\u2011B\/Din\u2011U\/Personnalis\u00e9\u2011K<\/td>\n<td>GFHVT1500\u2011100X\u201174E<\/td>\n<td>100A<\/td>\n<td>1150<\/td>\n<td>4680<\/td>\n<td>48<\/td>\n<td>60<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>Boulonn\u00e9\u2011B\/Din\u2011U\/Personnalis\u00e9\u2011K<\/td>\n<td>GFHVT1500\u2011125X\u201174E<\/td>\n<td>125A<\/td>\n<td>1750<\/td>\n<td>8350<\/td>\n<td>52<\/td>\n<td>68<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>Boulonn\u00e9\u2011B\/Din\u2011U\/Personnalis\u00e9\u2011K<\/td>\n<td>GFHVT1500\u2011160X\u201174E<\/td>\n<td>160A<\/td>\n<td>3800<\/td>\n<td>14000<\/td>\n<td>68<\/td>\n<td>90<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>Boulonn\u00e9\u2011B\/Din\u2011U\/Personnalis\u00e9\u2011K<\/td>\n<td>GFHVT1500\u2011200X\u201174E<\/td>\n<td>200A<\/td>\n<td>5200<\/td>\n<td>23500<\/td>\n<td>82<\/td>\n<td>110<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>Boulonn\u00e9\u2011B\/Din\u2011U\/Personnalis\u00e9\u2011K<\/td>\n<td>GFHVT1500\u2011250X\u201174E<\/td>\n<td>250 A<\/td>\n<td>10400<\/td>\n<td>45000<\/td>\n<td>92<\/td>\n<td>120<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>Boulonn\u00e9\u2011B\/Din\u2011U\/Personnalis\u00e9\u2011K<\/td>\n<td>GFHVT1500\u2011315X\u201174E<\/td>\n<td>315A<\/td>\n<td>21238<\/td>\n<td>76760<\/td>\n<td>104<\/td>\n<td>136<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>Boulonn\u00e9\u2011B\/Din\u2011U\/Personnalis\u00e9\u2011K<\/td>\n<td>GFHVT1500\u2011350X\u201174E<\/td>\n<td>350A<\/td>\n<td>29180<\/td>\n<td>104691<\/td>\n<td>113<\/td>\n<td>148<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>Boulonn\u00e9\u2011B\/Din\u2011U\/Personnalis\u00e9\u2011K<\/td>\n<td>GFHVT1500\u2011400X\u201174E<\/td>\n<td>400A<\/td>\n<td>38468<\/td>\n<td>136083<\/td>\n<td>130<\/td>\n<td>171<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>Boulonn\u00e9\u2011B\/Din\u2011U\/Personnalis\u00e9\u2011K<\/td>\n<td>GFHVT1500\u2011450X\u201174E<\/td>\n<td>450A<\/td>\n<td>54749<\/td>\n<td>192815<\/td>\n<td>143<\/td>\n<td>187<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>Boulonn\u00e9\u2011B\/Din\u2011U\/Personnalis\u00e9\u2011K<\/td>\n<td>GFHVT1500\u2011500X\u201174E<\/td>\n<td>500A<\/td>\n<td>74371<\/td>\n<td>259379<\/td>\n<td>155<\/td>\n<td>204<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>Boulonn\u00e9\u2011B\/Din\u2011U\/Personnalis\u00e9\u2011K<\/td>\n<td>GFHVT1500\u2011550X\u201174E<\/td>\n<td>550A<\/td>\n<td>93073<\/td>\n<td>317075<\/td>\n<td>169<\/td>\n<td>221<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>Boulonn\u00e9\u2011B\/Din\u2011U\/Personnalis\u00e9\u2011K<\/td>\n<td>GFHVT1500\u2011630X\u201174E<\/td>\n<td>630A<\/td>\n<td>131578<\/td>\n<td>437610<\/td>\n<td>189<\/td>\n<td>248<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>Boulonn\u00e9\u2011B\/Din\u2011U\/Personnalis\u00e9\u2011K<\/td>\n<td>GFHVT1500\u2011700X\u201174E<\/td>\n<td>700A<\/td>\n<td>182476<\/td>\n<td>593977<\/td>\n<td>202<\/td>\n<td>273<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>Boulonn\u00e9\u2011B\/Din\u2011U\/Personnalis\u00e9\u2011K<\/td>\n<td>GFHVT1500\u2011800X\u201174E<\/td>\n<td>800A<\/td>\n<td>283377<\/td>\n<td>893774<\/td>\n<td>218<\/td>\n<td>294<\/td>\n<td>\u25cf<\/td>\n<td>\u25cf<\/td>\n<\/tr>\n<tr>\n<td>Boulonn\u00e9\u2011B\/Din\u2011U\/Personnalis\u00e9\u2011K<\/td>\n<td>GFHVT1500\u2011900X\u201174E<\/td>\n<td>900A<\/td>\n<td>408596<\/td>\n<td>1247411<\/td>\n<td>237<\/td>\n<td>305<\/td>\n<td>\uffee<\/td>\n<td>\uffee<\/td>\n<\/tr>\n<tr>\n<td>Boulonn\u00e9\u2011B\/Din\u2011U\/Personnalis\u00e9\u2011K<\/td>\n<td>GFHVT1500\u20111000X\u201174E<\/td>\n<td>1000A<\/td>\n<td>546988<\/td>\n<td>1605152<\/td>\n<td>282<\/td>\n<td>362<\/td>\n<td>\uffee<\/td>\n<td>\uffee<\/td>\n<\/tr>\n<tr>\n<td>Boulonn\u00e9\u2011B\/Din\u2011U\/Personnalis\u00e9\u2011K<\/td>\n<td>GFHVT1500\u20111100X\u201174E<\/td>\n<td>1100A<\/td>\n<td>751540<\/td>\n<td>2129888<\/td>\n<td>300<\/td>\n<td>385<\/td>\n<td>\uffee<\/td>\n<td>\uffee<\/td>\n<\/tr>\n<tr>\n<td>Boulonn\u00e9\u2011B\/Din\u2011U\/Personnalis\u00e9\u2011K<\/td>\n<td>GFHVT1500\u20111200X\u201174E<\/td>\n<td>1200A<\/td>\n<td>991418<\/td>\n<td>2779209<\/td>\n<td>305<\/td>\n<td>391<\/td>\n<td>\uffee<\/td>\n<td>\uffee<\/td>\n<\/tr>\n<tr>\n<td>Boulonn\u00e9\u2011B\/Din\u2011U\/Personnalis\u00e9\u2011K<\/td>\n<td>GFHVT1500\u20111250X\u201174E<\/td>\n<td>1250A<\/td>\n<td>1121162<\/td>\n<td>3162024<\/td>\n<td>314<\/td>\n<td>401<\/td>\n<td>\uffee<\/td>\n<td>\uffee<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<blockquote><p>Remarque\u00a0: X \u00e0 remplacer par B\/U\/K. \u25cf = Disponible\u00a0; \uffee = Proc\u00e9dure d\u2019application \u00e0 d\u00e9terminer\u00a0; 1250A\u00a0: consulter d\u2019abord le fabricant.<\/p><\/blockquote>\n<h2>Domaines d&#039;application<\/h2>\n<ul>\n<li>\u26a1 <strong>Bloc-batterie et syst\u00e8me de stockage d&#039;\u00e9nergie (BESS)<\/strong> protection du circuit principal<\/li>\n<li>\u26a1 Protection de secours contre les courts-circuits pour les relais et contacteurs CC<\/li>\n<li>\u26a1 Armoire de stockage d&#039;\u00e9nergie, protection contre les surintensit\u00e9s et les courts-circuits des barres omnibus CC<\/li>\n<li>\u26a1 Sectionneur de s\u00e9curit\u00e9 pour la maintenance \/ application d&#039;isolation CC<\/li>\n<li>\u26a1 \u00c9quipement de stockage d&#039;\u00e9nergie industriel \u00e0 courant continu haute intensit\u00e9<\/li>\n<\/ul>\n<h2>Normes et certifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Norme \/ Certificat<\/th>\n<th>Statut<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>UL 248.1, UL 248.13<\/td>\n<td>Conforme (\u2264800A)<\/td>\n<\/tr>\n<tr>\n<td>CEI 60269-1, CEI 60269-4<\/td>\n<td>Conforme (\u2264800A)<\/td>\n<\/tr>\n<tr>\n<td>RoHS<\/td>\n<td>Conforme<\/td>\n<\/tr>\n<tr>\n<td>ATTEINDRE<\/td>\n<td>D\u00e9claration disponible sur demande<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<blockquote><p>Remarque : Les puissances nominales 900\u20111250A sont en attente de certification compl\u00e8te, veuillez consulter l&#039;usine pour la qualification du projet.<\/p><\/blockquote>\n<h2>Conditions de fonctionnement et de d\u00e9classement<\/h2>\n<blockquote><p>Important : Courant de fonctionnement continu recommand\u00e9 \u226475 % du calibre nominal du fusible dans des conditions standard.<\/p><\/blockquote>\n<h3>D\u00e9classement en fonction de la temp\u00e9rature ambiante<\/h3>\n<p>Au-dessus de 40 \u00b0C de temp\u00e9rature ambiante, un d\u00e9classement du courant est n\u00e9cessaire conform\u00e9ment \u00e0 la courbe de d\u00e9classement. En dessous de -5 \u00b0C, le temps de pr\u00e9-amor\u00e7age pour une faible surcharge sera l\u00e9g\u00e8rement prolong\u00e9.<\/p>\n<h3>D\u00e9classement en altitude<\/h3>\n<p>Altitude de fonctionnement normale \u2264 2\u00a0000 m. Pour les applications en enceinte ferm\u00e9e \u00e0 une altitude de 2\u00a0000 \u00e0 4\u00a0500 m\u00a0: r\u00e9duire le courant nominal. <strong>2 \u00e0 5 TP3T par 1000 m d&#039;augmentation<\/strong>. La r\u00e9sistance \u00e0 l&#039;isolation thermique diminue en haute altitude ; v\u00e9rifier le d\u00e9gagement conform\u00e9ment \u00e0 la norme GB\/T 16935.1.<\/p>\n<h3>Correction du refroidissement par air puls\u00e9<\/h3>\n<p>La ventilation forc\u00e9e am\u00e9liore la dissipation de la chaleur et augmente le courant continu admissible. Se r\u00e9f\u00e9rer \u00e0 la courbe de correction Kv en fonction de la vitesse du vent (m\/s).<\/p>\n<h2>Courbes caract\u00e9ristiques temps-courant<\/h2>\n<p>Deux s\u00e9ries de courbes TCC couvrent les plages de valeurs nominales 100-800 A et 900-1250 A. Tol\u00e9rance de la courbe\u00a0: \u00b115 % sur l\u2019axe du courant. Courant de coupure minimal = 5 \u00d7 In.<\/p>\n<h2>Foire aux questions<\/h2>\n<p><strong>1 : Quel est le courant de coupure minimal pour la s\u00e9rie GFHVT1500\u201174E ?<\/strong><\/p>\n<p>1 : Le courant de coupure minimum est 5 fois le courant nominal (5In).<\/p>\n<p><strong>2 : Le GFHVT1500\u201174E peut-il \u00eatre utilis\u00e9 pour la protection contre les courts-circuits des batteries lithium-ion ?<\/strong><\/p>\n<p>2 : Oui. Il est con\u00e7u pour la protection du circuit principal CC des batteries et des syst\u00e8mes de stockage d&#039;\u00e9nergie, sous forme de fusible rapide. V\u00e9rifiez sa compatibilit\u00e9 avec votre syst\u00e8me de gestion de batterie (BMS).<\/p>\n<p><strong>3 : Quel coefficient de r\u00e9duction dois-je appliquer pour une installation d&#039;armoire ferm\u00e9e en haute altitude ?<\/strong><\/p>\n<p>3 : Pour les armoires \u00e9tanches au-dessus de 2000 m d&#039;altitude, r\u00e9duire de 2 \u00e0 5 % par 1000 m d&#039;altitude ; les fusibles de plus grande ampacit\u00e9 adoptent un pourcentage de r\u00e9duction plus \u00e9lev\u00e9.<\/p>\n<p><strong>4 : Que signifient les trois codes de connexion B\/U\/K ?<\/strong><\/p>\n<p>4 : B = Connexion \u00e0 barre longue boulonn\u00e9e ; U = Fourche DIN ; K = Fourche personnalis\u00e9e pour montage vertical.<\/p>\n<p><strong>5 : Les mod\u00e8les 900A\u20111250A sont-ils enti\u00e8rement certifi\u00e9s ?<\/strong><\/p>\n<p>Le processus de certification des mod\u00e8les 5: 900-1250A est en cours. Veuillez contacter le service d&#039;ing\u00e9nierie d&#039;EssFuse pour une \u00e9valuation de votre projet avant toute sp\u00e9cification.<\/p>\n<h2>T\u00e9l\u00e9charger la fiche technique et les ressources<\/h2>\n<p>\ud83d\udcc4 <strong>T\u00e9l\u00e9charger la fiche technique de la s\u00e9rie GFHVT1500\u201174E (PDF)<\/strong> <a href=\"https:\/\/gfevfuse.com\/wp-content\/uploads\/2026\/09\/GFHVT1500-74E-Series.-100-1250A-1500Vdc-IR.250kA-fast-acting-fuse-1.pdf\">GFHVT1500-74E-S\u00e9rie.-100-1250A-1500Vcc-IR.250kA fusible \u00e0 action rapide-1<\/a><\/p>\n<blockquote><p>&nbsp;<\/p><\/blockquote>","protected":false},"excerpt":{"rendered":"<p>Fusible CC \u00e0 corps carr\u00e9 GFHVT1500-74E, 1500 Vcc, 100-1250 A, pouvoir de coupure de 250 kA. Conforme aux normes UL\/IEC pour la protection de secours des syst\u00e8mes de stockage d&#039;\u00e9nergie par batterie (BESS), des blocs-batteries et des relais CC. T\u00e9l\u00e9charger la fiche technique.<\/p>","protected":false},"featured_media":31177,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[93],"product_tag":[],"class_list":["post-31176","product","type-product","status-publish","has-post-thumbnail","product_cat-square-high-speed-fuse","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/product\/31176","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/comments?post=31176"}],"version-history":[{"count":3,"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/product\/31176\/revisions"}],"predecessor-version":[{"id":32680,"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/product\/31176\/revisions\/32680"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/media\/31177"}],"wp:attachment":[{"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/media?parent=31176"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/product_brand?post=31176"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/product_cat?post=31176"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/product_tag?post=31176"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}