{"id":31054,"date":"2026-09-24T02:02:58","date_gmt":"2026-09-24T02:02:58","guid":{"rendered":"https:\/\/gfevfuse.com\/?post_type=product&#038;p=31054"},"modified":"2026-11-10T00:37:51","modified_gmt":"2026-11-10T00:37:51","slug":"gfevt1000-36e-1000vdc-fast-acting-dc-fuse-250-400a","status":"publish","type":"product","link":"https:\/\/gfevfuse.com\/fr\/gfevt1000-36e-1000vdc-fast-acting-dc-fuse-250-400a\/","title":{"rendered":"Fusible CC \u00e0 corps carr\u00e9 \u00e0 action rapide 1000 Vcc s\u00e9rie GFEVT1000\u201136E\u2011 (250 A\u2011400 A, taille 00#, classe aR)"},"content":{"rendered":"<h3>Fusible CC \u00e0 corps carr\u00e9 \u00e0 action rapide 1000 Vcc s\u00e9rie GFEVT1000\u201136E\u2011 (250 A\u2011400 A, taille 00#, classe aR)<\/h3>\n<blockquote><p>\u00a0Le <strong>Fusible CC \u00e0 corps carr\u00e9 \u00e0 action rapide s\u00e9rie GFEVT1000-36E<\/strong>\u00a0 est un fusible haute vitesse de classe aR <strong>1000 Vcc<\/strong>, couvrant <strong>250 A, 315 A, 350 A et 400 A<\/strong> dans un format compact (taille 00#). Con\u00e7u sp\u00e9cifiquement pour les syst\u00e8mes de stockage d&#039;\u00e9nergie \u00e9lectrique et la protection des batteries lithium-ion, il offre <strong>Pouvoir de coupure de 50 kA \u00e0 1000 Vcc avec L\/R \u2264 3 ms<\/strong> et courant de coupure minimal de <strong>3,0\u00d7po<\/strong>. Deux options de montage sont disponibles\u00a0: <strong>C\u201136E<\/strong> version \u00e0 crochets fixes et la <strong>U\u201136E<\/strong> Version \u00e0 terminal fork.<\/p><\/blockquote>\n<h3>Foire aux questions<\/h3>\n<p><strong>1 : Quelle est la capacit\u00e9 de coupure et la constante de temps du GFEVT1000\u201136E ?<\/strong><\/p>\n<blockquote><p>A : La capacit\u00e9 de coupure nominale est <strong>50 kA \u00e0 1000 Vcc<\/strong>, avec une constante de temps <strong>G\/D \u2264 3 ms<\/strong>; le courant de coupure minimal est <strong>3,0\u00d7po<\/strong>.<\/p><\/blockquote>\n<p><strong>2 : Quelles sont les deux versions de montage ?<\/strong><\/p>\n<blockquote><p>UN: <strong>\u2011C\u201136E<\/strong> livr\u00e9 avec des supports de montage fixes (type support) ; <strong>\u2011U\u201136E<\/strong> Utilise des bornes de type fourche. Les deux mod\u00e8les partagent le m\u00eame corps carr\u00e9 00#, mais diff\u00e8rent par leur hauteur totale et la disposition de leurs bornes.<\/p><\/blockquote>\n<p><strong>3 : Quelles sont les valeurs nominales de courant disponibles ?<\/strong><\/p>\n<blockquote><p>A: Quatre \u00e9valuations : <strong>250 A, 315 A, 350 A et 400 A<\/strong>, disponible dans les configurations C\u201136E et U\u201136E.<\/p><\/blockquote>\n<p><strong>4 : Quel est le courant de fonctionnement continu recommand\u00e9 ?<\/strong><\/p>\n<blockquote><p>A: Un courant r\u00e9gulier doit \u00eatre maintenu. <strong>\u2264 75% du courant nominal recommand\u00e9<\/strong>.<\/p><\/blockquote>\n<p><strong>5 : Ce fusible est-il conforme aux normes UL et IEC ?<\/strong><\/p>\n<blockquote><p>A : Les normes de r\u00e9f\u00e9rence sont <strong>UL 248.1 \/ UL 248.13<\/strong> et <strong>CEI 60269\u20111 \/ CEI 60269.4<\/strong>. Conforme \u00e0 la directive RoHS ; d\u00e9claration REACH disponible sur demande.<\/p><\/blockquote>\n<p><strong>6 : Une r\u00e9duction de puissance en altitude est-elle n\u00e9cessaire ?<\/strong><\/p>\n<blockquote><p>A : L&#039;altitude standard est \u2264 2\u00a0000 m. Pour les armoires ferm\u00e9es o\u00f9 la temp\u00e9rature interne reste sup\u00e9rieure \u00e0 40 \u00b0C au-dessus de 2\u00a0000 m, r\u00e9duire le courant nominal de <strong>2%\u20135% par 1000 m d&#039;\u00e9l\u00e9vation<\/strong>. Les installations en plein air peuvent g\u00e9n\u00e9ralement ignorer cet effet.<\/p><\/blockquote>\n<h3>Pr\u00e9sentation du produit<\/h3>\n<p>Le GFEVT1000\u201136E est un fusible rapide compact de type 00# \u00e0 corps carr\u00e9, con\u00e7u pour les circuits CC exigeants de 1\u00a0000\u00a0Vcc. Sa tension nominale plus \u00e9lev\u00e9e permet l\u2019utilisation de conducteurs plus petits et plus \u00e9conomiques, tout en am\u00e9liorant l\u2019efficacit\u00e9 globale du syst\u00e8me. En cas de courant de d\u00e9faut \u00e9lev\u00e9, il s\u2019ouvre pour <strong>10 fois plus rapide<\/strong> Plus performant que les fusibles classiques, il assure une protection fiable des circuits et des composants. Il offre une capacit\u00e9 de courant plus \u00e9lev\u00e9e tout en respectant les dimensions autoris\u00e9es, une excellente r\u00e9sistance aux surtensions et une large plage de temp\u00e9ratures ambiantes. Sa r\u00e9sistance sup\u00e9rieure aux vibrations et aux chocs m\u00e9caniques le rend id\u00e9al pour les applications de stockage d&#039;\u00e9nergie en armoire et mobiles.<\/p>\n<h3>Principales caract\u00e9ristiques et avantages<\/h3>\n<ul>\n<li>\u2705 Tension nominale <strong>1000 Vcc<\/strong> \u2014 permet l&#039;utilisation de conducteurs plus petits et moins co\u00fbteux, ainsi qu&#039;une efficacit\u00e9 globale du syst\u00e8me plus \u00e9lev\u00e9e<\/li>\n<li>\u2705 Conception \u00e0 action rapide \u2014 s&#039;ouvre pour <strong>10 fois plus rapide<\/strong> sous fort courant de d\u00e9faut, protection des batteries et des semi-conducteurs de puissance<\/li>\n<li>\u2705 Niveau d&#039;interruption <strong>50 kA \u00e0 1000 Vcc (L\/R \u2264 3 ms)<\/strong>; courant de coupure minimal <strong>3,0\u00d7po<\/strong>, classe R<\/li>\n<li>\u2705 Compact <strong>Taille 00#<\/strong> Corps carr\u00e9 \u2014 gain de place dans l&#039;armoire par rapport aux s\u00e9ries 2#\/3# plus grandes<\/li>\n<li>\u2705 Capacit\u00e9 de courant plus \u00e9lev\u00e9e disponible dans les limites des dimensions recommand\u00e9es\u00a0; excellente capacit\u00e9 de cyclisme<\/li>\n<li>\u2705 Faibles pertes en watts ; forte r\u00e9sistance aux impulsions de tension et aux temp\u00e9ratures ambiantes extr\u00eames<\/li>\n<li>\u2705 Deux styles de montage : <strong>C\u201136E<\/strong> support fixe, <strong>U\u201136E<\/strong> terminal de fourche<\/li>\n<li>\u2705 Conforme \u00e0 la directive RoHS ; d\u00e9claration REACH disponible sur demande<\/li>\n<\/ul>\n<h3>Caract\u00e9ristiques \u00e9lectriques principales<\/h3>\n<table>\n<thead>\n<tr>\n<th>Article<\/th>\n<th>Sp\u00e9cification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Tension nominale<\/td>\n<td>1000 Vcc<\/td>\n<\/tr>\n<tr>\n<td>Plage de courant nominal<\/td>\n<td>250 A \/ 315 A \/ 350 A \/ 400 A (Taille 00#)<\/td>\n<\/tr>\n<tr>\n<td>Classe op\u00e9rationnelle<\/td>\n<td>aR (protection des semi-conducteurs\/batteries \u00e0 haute vitesse)<\/td>\n<\/tr>\n<tr>\n<td>Capacit\u00e9 de rupture nominale<\/td>\n<td>50 kA \u00e0 1000 Vcc, L\/R \u2264 3 ms<\/td>\n<\/tr>\n<tr>\n<td>Courant de coupure minimal<\/td>\n<td>\u2265 3,0 \u00d7 Dans<\/td>\n<\/tr>\n<tr>\n<td>Testez la condition I\u00b2t<\/td>\n<td>50 kA \u00e0 1000 Vcc<\/td>\n<\/tr>\n<tr>\n<td>Tol\u00e9rance de la courbe temps-courant<\/td>\n<td>\u00b115% erreur de direction du courant<\/td>\n<\/tr>\n<tr>\n<td>Courant continu recommand\u00e9<\/td>\n<td>\u2264 75% de calibre nominal du fusible<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Tableau complet des cotes de r\u00e9f\u00e9rence<\/h3>\n<p><strong>C\u201136E (type \u00e0 support fixe)<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Num\u00e9ro de pi\u00e8ce.<\/th>\n<th>Amp\u00e8res du fusible<\/th>\n<th>Capacit\u00e9 de rupture<\/th>\n<th>Fusion de l&#039;A\u00b2s \u00e0 50 kA\/1000 Vcc<\/th>\n<th>\u00c9limination A\u00b2s \u00e0 50 kA\/1000 Vcc<\/th>\n<th>Perte de puissance (W)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>GFEVT1000\u2011250C\u201136E<\/td>\n<td>250 A<\/td>\n<td>50 kA<\/td>\n<td>23,000<\/td>\n<td>100,800<\/td>\n<td>45<\/td>\n<\/tr>\n<tr>\n<td>GFEVT1000\u2011315C\u201136E<\/td>\n<td>315A<\/td>\n<td>50 kA<\/td>\n<td>37,400<\/td>\n<td>157,500<\/td>\n<td>65<\/td>\n<\/tr>\n<tr>\n<td>GFEVT1000\u2011350C\u201136E<\/td>\n<td>350A<\/td>\n<td>50 kA<\/td>\n<td>45,360<\/td>\n<td>190,800<\/td>\n<td>80<\/td>\n<\/tr>\n<tr>\n<td>GFEVT1000\u2011400C\u201136E<\/td>\n<td>400A<\/td>\n<td>50 kA<\/td>\n<td>68,500<\/td>\n<td>287,000<\/td>\n<td>88<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>U\u201136E (type terminal \u00e0 fourche)<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Num\u00e9ro de pi\u00e8ce.<\/th>\n<th>Amp\u00e8res du fusible<\/th>\n<th>Capacit\u00e9 de rupture<\/th>\n<th>Fusion de l&#039;A\u00b2s \u00e0 50 kA\/1000 Vcc<\/th>\n<th>\u00c9limination A\u00b2s \u00e0 50 kA\/1000 Vcc<\/th>\n<th>Perte de puissance (W)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>GFEVT1000\u2011250U\u201136E<\/td>\n<td>250 A<\/td>\n<td>50 kA<\/td>\n<td>23,000<\/td>\n<td>100,800<\/td>\n<td>48<\/td>\n<\/tr>\n<tr>\n<td>GFEVT1000\u2011315U\u201136E<\/td>\n<td>315A<\/td>\n<td>50 kA<\/td>\n<td>37,400<\/td>\n<td>157,500<\/td>\n<td>68<\/td>\n<\/tr>\n<tr>\n<td>GFEVT1000\u2011350U\u201136E<\/td>\n<td>350A<\/td>\n<td>50 kA<\/td>\n<td>45,360<\/td>\n<td>190,800<\/td>\n<td>82<\/td>\n<\/tr>\n<tr>\n<td>GFEVT1000\u2011400U\u201136E<\/td>\n<td>400A<\/td>\n<td>50 kA<\/td>\n<td>68,500<\/td>\n<td>287,000<\/td>\n<td>90<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h3>Dimensions m\u00e9caniques (C\u201136E \/ U\u201136E)<\/h3>\n<ol>\n<li><strong>GFEVT1000\u2011xxxC\u201136E<\/strong> \u2014 supports de montage fixes, longueur totale du corps 74,5\u00b12 mm, largeur du corps 36,3\u00b11 mm, hauteur du corps 32,5\u00b11 mm ; empreinte de la plaque de montage 118\u00b12 mm \u00d7 100\u00b12 mm, pas des trous 92\u00b12 mm, diam\u00e8tre des trous 6,5\u00b10,5 mm.<\/li>\n<li><strong>GFEVT1000\u2011xxxU\u201136E<\/strong> \u2014 bornes \u00e0 fourche, longueur totale du corps 74,5\u00b12 mm, largeur du corps 28\u00b11 mm, hauteur du corps 41\u00b11 mm ; pas de montage 115\u00b12 mm \u00d7 95\u00b12 mm, fente du trou 15,3\u00b10,5 mm.<\/li>\n<\/ol>\n<blockquote><p>&nbsp;<\/p><\/blockquote>\n<h3>Domaines d&#039;application<\/h3>\n<ul>\n<li><strong>Stockage d&#039;\u00e9nergie \u00e9lectrique (ESS \/ BESS)<\/strong> protection contre les surintensit\u00e9s et les courts-circuits<\/li>\n<li><strong>protection du bloc-batterie lithium-ion<\/strong> pour les v\u00e9hicules \u00e0 \u00e9nergies nouvelles et le stockage stationnaire<\/li>\n<li><strong>Protection de secours pour relais CC<\/strong> \/ Contacteur CC<\/li>\n<li>Armoires de distribution \u00e9lectrique \u00e0 courant continu haute tension<\/li>\n<li>Protection des \u00e9quipements d&#039;alimentation CC industriels et des convertisseurs<\/li>\n<\/ul>\n<h3>Normes et homologations<\/h3>\n<ul>\n<li>Norme de r\u00e9f\u00e9rence\u00a0: <strong>UL 248.1, UL 248.13\u00a0; CEI 60269\u20111, CEI 60269.4<\/strong><\/li>\n<li><strong>Conforme \u00e0 la directive RoHS<\/strong> tout au long de la s\u00e9rie<\/li>\n<li><strong>ATTEINDRE<\/strong> d\u00e9claration disponible sur demande du client<\/li>\n<li>Pr\u00e9cision de la caract\u00e9ristique temps-courant\u00a0: erreur de direction du courant de \u00b115%<\/li>\n<\/ul>\n<h3>Conditions de fonctionnement et r\u00e8gles de d\u00e9classement<\/h3>\n<ol>\n<li><strong>temp\u00e9rature de stockage<\/strong>: \u201140\u00b0C ~ +120\u00b0C; stockage de l&#039;emballage : \u201140\u00b0C ~ +80\u00b0C.<\/li>\n<li><strong>Humidit\u00e9<\/strong>: T\u226440\u00b0C RH\u226470%; T\u226430\u00b0C RH\u226480%; T\u226420\u00b0C RH\u226490%.<\/li>\n<li><strong>Temp\u00e9rature ambiante<\/strong>Temp\u00e9rature de fonctionnement standard : -5 \u00b0C \u00e0 +40 \u00b0C ; temp\u00e9rature admissible : -40 \u00b0C \u00e0 +85 \u00b0C. Au-del\u00e0 de 40 \u00b0C, appliquer un facteur de r\u00e9duction de temp\u00e9rature. <strong>Kt<\/strong>; en dessous de \u20115\u00b0C, le temps de pr\u00e9-amor\u00e7age \u00e0 faible surcharge s\u2019allonge l\u00e9g\u00e8rement.<\/li>\n<li><strong>Altitude Ka<\/strong>Altitude standard \u2264 2\u00a0000\u00a0m. Pour les armoires ferm\u00e9es o\u00f9 la temp\u00e9rature interne reste sup\u00e9rieure \u00e0 40\u00a0\u00b0C au-dessus de 2\u00a0000\u00a0m, r\u00e9duire la puissance. <strong>2%\u20135% pour 1000 m<\/strong>. La r\u00e9sistance \u00e0 l&#039;isolation \u00e0 l&#039;air diminue de 12% \u00e0 15% par 1\u00a0000\u00a0m entre 2\u00a0000 et 4\u00a0500\u00a0m\u00a0; se r\u00e9f\u00e9rer \u00e0 la norme GB\/T16935.1 pour la correction des d\u00e9gagements. Formule de correction\u00a0: <strong>Ka = 1 \u2013 (H \u2013 2000)\/100 \u00d7 (0,5\/100)<\/strong>.<\/li>\n<li><strong>Courant r\u00e9gulier<\/strong>: Doit \u00eatre <strong>\u226475% de courant nominal recommand\u00e9<\/strong>.<\/li>\n<\/ol>\n<blockquote><p>&nbsp;<\/p><\/blockquote>\n<h3>Exigences relatives \u00e0 l&#039;installation et au dimensionnement des conducteurs<\/h3>\n<ul>\n<li>Le courant de passage r\u00e9gulier ne doit pas d\u00e9passer 75% du courant nominal du fusible.<\/li>\n<li>S\u00e9lectionnez la section transversale du conducteur de cuivre de raccordement en fonction du courant continu \u00e0 long terme : par exemple 250 A \u2192 ~120 mm\u00b2 ; 315\u2013400 A \u2192 ~185\u2013240 mm\u00b2 (reportez-vous au tableau des conducteurs dans la fiche technique).<\/li>\n<li>Pour la classe 1250\u20132000A, utilisez 1,0\u20131,4A\/mm\u00b2 ; pour 2000\u20133000A, utilisez 0,9\u20131,0A\/mm\u00b2.<\/li>\n<li>Faire <strong>pas<\/strong> Remplacez le fusible sous charge, sauf si un interrupteur-sectionneur de fusible d\u00e9di\u00e9 est utilis\u00e9.<\/li>\n<li>Maintenez un d\u00e9gagement d&#039;isolation suffisant entre les pi\u00e8ces sous tension et entre le fusible et la terre ; les installations en haute altitude n\u00e9cessitent une attention particuli\u00e8re au d\u00e9gagement conform\u00e9ment \u00e0 la norme GB\/T16935.1.<\/li>\n<li>Les bornes des fusibles doivent rester propres et pr\u00e9senter une faible r\u00e9sistance de contact stable\u00a0; remplacer tout fusible pr\u00e9sentant des dommages m\u00e9caniques.<\/li>\n<\/ul>\n<h3>T\u00e9l\u00e9charger la fiche technique et obtenir un devis<\/h3>\n<p>\ud83d\udc49 <a href=\"https:\/\/gfevfuse.com\/wp-content\/uploads\/2026\/09\/GFEVT1000-36E-Series.-00.-250-400A-1000Vdc-fast-acting-fuse.pdf\">Fusible \u00e0 action rapide GFEVT1000-36E-Series.-00.-250-400A-1000Vcc<\/a>| Demande d&#039;assistance technique et de devis group\u00e9<\/p>","protected":false},"excerpt":{"rendered":"<p>Fusible CC \u00e0 action rapide GFEVT1000-36E, corps carr\u00e9, 1000 Vcc, 250-400 A, pouvoir de coupure de 50 kA (L\/R \u2264 3 ms), classe R pour batteries et syst\u00e8mes de stockage d'\u00e9nergie. Conforme aux normes UL248.13, IEC60269.4 et RoHS. Demandez la fiche technique et un devis.<\/p>","protected":false},"featured_media":31056,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[93],"product_tag":[],"class_list":["post-31054","product","type-product","status-publish","has-post-thumbnail","product_cat-square-high-speed-fuse","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/product\/31054","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/comments?post=31054"}],"version-history":[{"count":3,"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/product\/31054\/revisions"}],"predecessor-version":[{"id":32654,"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/product\/31054\/revisions\/32654"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/media\/31056"}],"wp:attachment":[{"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/media?parent=31054"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/product_brand?post=31054"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/product_cat?post=31054"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/gfevfuse.com\/fr\/wp-json\/wp\/v2\/product_tag?post=31054"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}